Zde můžete vidět rozdíly mezi vybranou verzí a aktuální verzí dané stránky.
— |
howto:electro:gigabit_poe [2014/12/11 17:20] (aktuální) |
||
---|---|---|---|
Řádek 1: | Řádek 1: | ||
+ | ====== Gigabit PoE (802.3af) ====== | ||
+ | * http://en.wikipedia.org/wiki/Power_over_Ethernet#Power_capacity_limits | ||
+ | * http://forum.mikrotik.com/download/file.php?id=10417&sid=6fc2e8eb2c2daca423ee4b91e19a1405 | ||
+ | * http://www.dipolnet.cz/poe_-_iee_802_3af_and_iee_802_3at_bib746.htm | ||
+ | |||
+ | * **C = 100nF** (ceramic, stacked tin foil,...) | ||
+ | * **L = 300uH** | ||
+ | * Ferrite material 43 or 61 (toroid FT-37-61) | ||
+ | * https://www.youtube.com/watch?v=t8mB6xz2NPI | ||
+ | |||
+ | {{http://www.valal.sk/upload/savefile_php/uploads/eb025411ea.png}} | ||
+ | {{http://www.infocellar.com/networks/new-tech/PoE/cable2.gif}} | ||
+ | {{http://electronicdesign.com/site-files/electronicdesign.com/files/uploads/2014/01/fig1.gif}} | ||
+ | |||
+ | ===== Experiments ===== | ||
+ | |||
+ | * I've decoupled all of 8 gigabit ethernet conductors using 100nF ceramic capacitors and the link was still OK. | ||
+ | * I've shorted + and - of 3 meters 100M ethernet pair through FT-50-61 toroid choke. For 4 and more windings it did not affected the link. When removing the winds the link quality was getting gradually worse. | ||
+ | * I've put FT-50-61 toroid choke on + of the same pair and from 9-10 winds and up it prevented the ethernet from linking. When trying less winds the link quality was gradually better. | ||
+ | * It's not good idea to use wire with 0.2mm diameter for more than 3A (too much voltage drop, too much heat). So probably 2A should be maximum. |